Brand Name :WINLEY
Model Number :SCB10-1250/0.48
Certification :CE,ISO
Place of Origin :CHINA
MOQ :1unit
Price :$5000-$100000
Payment Terms :T/T
Supply Ability :1000set/month
Delivery Time :30days
Packaging Details :Plywood case
Type :Cast Coil Isolation Transformer
Rated capacity :6500KVA
Primary voltage :33000V
Secondary voltage :900
Cooling method :AN/AF
Winding material :Aluminum
Temperature rise :100℃
Standard :AS60076&AS3000
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

6500kva Cast Coil epoxy resin Transformer Dry Type 33000V To 900V AS60076



Winley’s 6,500 kVA dry‑type cast resin transformer is engineered for reliable, low‑maintenance power distribution in commercial, industrial and utility indoor installations. Designed and manufactured to AS 60076 and AS 3000 standards, this transformer provides robust performance, excellent dielectric safety and low harmonic distortion for critical systems where fire safety, compact footprint and environmental friendliness are priorities.


Product Photos

6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards 6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

Main data

No. Particulars Unit Specification
1 Type ~ dry type, cast resin
2 Rated capacity kVA 6500
3 Duty ~ Continuous duty
4 No. of Phase ~ 3
5 Primary voltage V 33000
6 Secondary voltage V 900
7 Tapping type ~ off-circuit
8 Tapping range % ±2*2.5%
9 Cooling method ~ AN/AF
10 Rated frequency Hz 50
11 Vector group ~ Dyn11
12 Insulation class ~ F
13 Temperature rise 100

Technical drawings

Built in accordance with AS/NZS 60076 and wiring per AS/NZS 3000 to ensure regulatory compliance, safety and interoperability with Australian/New Zealand power systems.

6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

Standard Features

  • Cooling fans for AN/AF operation to maintain thermal margins under higher load or elevated ambient temperatures.
  • Temperature monitoring: Nine PT100 sensors on the low‑voltage winding plus a resistance temperature device for thorough thermal supervision and integration with protecting/control systems.
  • Wiring and identification: All wiring and heat shrink materials installed to AS/NZS 3000. Phase identification follows the color code — Phase A (a): red, Phase B (b): white, Phase C (c): blue.

6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

The transformers have the following characteristics:

  • Windings have high mechanical strength and no partial discharge.
  • Epoxy resin and insulating materials used for windings are non-flammable, will not burn from an electric arc, and no toxic gases will be given off when the resin is burned.
  • Envionmental adaptability with windings that will not absorb moisture and a special anti-rust protective coating that seals the core and frame.
  • Operates under one-hundred percent relative humidity and other severe ambient conditions.
  • Ability to switch on the device without pre-drying or long periods of service interruptions.
  • Excellent short-circuit and lighting impulse strength.
  • Cooled naturally by air (AN) and forced air cooling (AF) provided as an option to improve overload capacity.
  • Smaller dimensions, less weight, and space saving.
  • Oil drainage pits and fire extinguishing devices not required for operation.

Production process
6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards

High-voltage winding appliesvacuumpouring of padding epoxyresin which, at highlevel,reduces partial discharge capacity andelevates the electric strength of coils. The insideand outside of the winding is buildup with glassfiber grid overlaywhich strengthens thethemechanicalrobustnessandimprovesresistance of short-circuits and ensures the coilswill never crack.

Low-voltage winding applies the structure that windedby copper foil which solves the problem that the axle wouldpoint to the helix angle when winds and make the ampereturn of winding distribute evenly. Meanwhile, the coilsapplies axial fan which improves the heat dispersion.Between the layers of winding, it applies DMD epoxy resinpreliminary dip cloth and makes it whole solidificationfor

Inquiry Cart 0