37.5 KVA Vacuum Pressure Impregnated (VPI) Transformer 2.4KV To 240V DOE 2016 IEEE ANSI Three Phase Dry Type Ventilated
Overview
The Winley 37.5 kVA Vacuum Pressure Impregnated (VPI) dry-type transformer is engineered for reliable, high-efficiency power distribution in commercial and industrial environments. Designed and built to exceed industry standards, this unit offers robust insulation, low noise, and a compact footprint for pad- or floor-mounted installations indoors or outdoors (NEMA 3R).

Key Features
- Transformer Type: Vacuum Pressure Impregnated (VPI) dry-type, ventilated construction for long-term insulation reliability and moisture resistance.
- Capacity: 37.5 kVA (up to 6000kva)
- Voltage: Primary 240 V , Secondary 2400 V .
- Primary class 1.2 kV; secondary class 2.5 kV.
- Vector Group: II6.
- Insulation & Thermal: Class H insulation; 80°C temperature rise; temperature sensors and gauge included.
- Cooling & Fans: ANN (natural air cooling). No forced-air fans — lower maintenance and quieter operation.
- Winding Material: Copper for superior conductivity and reliability.
- Acoustic Performance: Approximately 55 dBA sound level for quiet operation in sensitive environments.
- Efficiency: Meets or exceeds DOE 2016 efficiency standards; typical operating efficiency up to 99.00% (measured at 50% of nameplate kVA).
- Losses: No-load losses approx. ±840 W; full-load losses approx. ±4,500 W; total load losses approx. ±5,340 W
- Mechanical: NEMA 3R coated steel enclosure with ANSI ; Pad mount or floor mount options.
- Altitude & Ambient Rating: Rated for operation up to 3,300 ft (1,000 m) elevation and ambient up to 40°C.
- Safety & Compliance: NRTL listed for the U.S. and Canada; complies with ANSI/IEEE C57.12.00, C57.12.01, C57.12.35, C57.12.59, C57.12.70; meets/exceeds CSA and NEMA ST-20 standards; RoHS and CE certified. Seismic bracing included for earthquake-specific installations.
Technical drawings

Benefits
- High reliability and long service life: VPI process and Class H insulation protect windings from moisture and contaminants and reduce partial discharges.
- Low maintenance: Natural air cooling (ANN) and no fans mean fewer moving parts to service.
- Energy efficiency: Designed to meet DOE 2016 efficiency levels, reducing operating costs and losses over the transformer lifecycle.
- Quiet operation: 55 dBA sound rating suits commercial or noise-sensitive installations.
- Safety and compliance: Constructed to meet major North American and international standards, simplifying approvals and permitting.
- Flexible installation: NEMA 3R weatherproof enclosure and seismic bracing enable indoor or outdoor pad- or floor-mounted installation.
Specification
Model (kva) | Primary Voltage | Secondary Voltage | Coupling group tab | Shape dimension | Mounting dimension | | K*J | The box dimension |
| Bmax | Dmax±5 | Emax | A | C±5 | Bmax | Dmax±5 | Emax |
| SG-10KVA | 660 400 380 200 | 380 220 110 36 | Yyn0 Y/d D/y D/d | 360 | 180 | 305 | 215 | 140 | 10*20 | 450 | 360 | 480 |
| SG-15KVA | 360 | 200 | 335 | 215 | 155 | 10*20 | 450 | 360 | 480 |
| SG-20KVA | 420 | 210 | 350 | 250 | 170 | 10*20 | 490 | 400 | 540 |
| SG-30KVA | 420 | 230 | 380 | 250 | 190 | 10*20 | 490 | 400 | 540 |
| SG-50KVA | 680 | 350 | 550 | 420 | 220 | 10*20 | 800 | 510 | 840 |
| SG-80KVA | 750 | 400 | 620 | 480 | 250 | 10*20 | 850 | 510 | 840 |
| SG-100KVA | 780 | 420 | 650 | 500 | 250 | 10*20 | 900 | 550 | 890 |
| SG-300KVA | 180 | 95 | 185 | 100 | 75 | 6*14 | | | |
| SG-500KVA | 180 | 95 | 185 | 100 | 75 | 6*14 | | | |
| SG-1000KVA | 180 | 110 | 185 | 100 | 90 | 6*14 | | | |
| SG-2000KVA | 230 | 125 | 205 | 130 | 100 | 9*16 | | | |
| SG-3000KVA | 240 | 145 | 215 | 130 | 120 | 9*16 | | | |
| SG-4000KVA | 240 | 155 | 235 | 130 | 130 | 9*16 | | | |
| SG-5000KVA | 320 | 160 | 255 | 180 | 115 | 10*20 | 400 | 330 | 480 |
| SG-6000KVA | 300 | 165 | 280 | 180 | 140 | 10*20 | 400 | 330 | 480 |